Typical use
|
<841> Specific gravity measurement (SG25/25, unless otherwise directed)
|
<831> Refractive index
(λ =589.3 nm, T=25, unless otherwise directed)
|
<781> Optical rotation
(λ = 589 nm, T=25 °C, l=1.00 dm, unless otherwise directed)
|
|
Amiloxate
|
Active pharmaceutical ingredient
|
1.037 to 1.041
|
1.556 to 1.560 at 20 °C
|
-
|
|
Amyl nitrite
|
Active pharmaceutical ingredient
|
0.870 to 0.876
|
-
|
-
|
|
Amyl nitrite inhalant
|
Active pharmaceutical ingredient
|
0.870 to 0.880
|
-
|
-
|
|
Malathion
|
Active pharmaceutical ingredient
|
1.220 to 1.240
|
-
|
-
|
|
Amylene hydrate
|
Active pharmaceutical ingredient
|
0.803 to 0.807
|
-
|
-
|
|
Benzyl benzoate
|
Active pharmaceutical ingredient
|
1.116 to 1.120
|
-
|
-
|
|
Collodion
|
Active pharmaceutical ingredient
|
0.765 to 0.775
|
-
|
-
|
|
Crotamiton
|
Active pharmaceutical ingredient
|
1.008 to 1.011 at 20 °C
|
1.540 to 1.543 at 20 °C
|
-
|
|
Diethyltoluamide
|
Active pharmaceutical ingredient
|
0.996 to 1.002
|
1.520 to 1.524
|
-
|
|
Dimercaprol
|
Active pharmaceutical ingredient
|
1.242 to 1.244
|
1.567 to 1.573
|
-
|
|
Flexible collodion
|
Active pharmaceutical ingredient
|
0.770 to 0.790
|
-
|
-
|
|
Halothane
|
Active pharmaceutical ingredient
|
1.872 to 1.877 at 20 °C
|
1.369 to 1.371 at 20 °C
|
-
|
|
Homosalate
|
Active pharmaceutical ingredient
|
1.049 to 1.053
|
1.516 to 1.519 at 20 °C
|
-
|
|
Juniper tar
|
Active pharmaceutical ingredient
|
0.950 to 1.055
|
-
|
-
|
|
Trolamine
|
Active pharmaceutical ingredient
|
1.120 to 1.128
|
1.481 to 1.486 at 20 °C
|
-
|
|
Trolamine salicylate
|
Active pharmaceutical ingredient
|
1.190 to 1.220
|
1.505 to 1.535 at 20 °C
|
-
|
|
Mineral oil, rectal
|
Active pharmaceutical ingredient
|
0.845 to 0.905
|
-
|
-
|
|
Octinoxate
|
Active pharmaceutical ingredient
|
1.005 to 1.013
|
1.542 to 1.548 at 20 °C
|
-
|
|
Octisalate
|
Active pharmaceutical ingredient
|
1.011 to 1.016
|
1.500 to 1.503 at 20 °C
|
-
|
|
Octocrylene
|
Active pharmaceutical ingredient
|
1.045 to 1.055
|
1.561 to 1.571 at 20 °C
|
-
|
|
Propylhexedrine
|
Active pharmaceutical ingredient
|
0.848 to 0.852
|
-
|
-
|
|
Resorcinol monoacetate
|
Active pharmaceutical ingredient
|
1.203 to 1.207
|
-
|
-
|
|
Undecylenic acid
|
Active pharmaceutical ingredient
|
0.910 to 0.913
|
1.447 to 1.448
|
-
|
|
Methyl salicylate
|
Active pharmaceutical ingredient
|
1.180 to 1.185 synthetic variety;
1.176 to 1.182 natural variety
|
-
|
-
|
|
Perflubron
|
Diagnostic agent
|
1.922 to 1.925
|
-
|
-
|
|
Ethiodized oil injection
|
Diagnostic agent
|
1.280 to 1.293 at 15 °C
|
-
|
-
|
|
Benzethonium chloride tincture
|
Pharmaceutical preparation
|
0.868 to 0.876
|
-
|
-
|
|
Camphorated phenol topical solution
|
Pharmaceutical preparation
|
0.840 to 0.865
|
-
|
-
|
|
Carbamide peroxide topical solution
|
Pharmaceutical preparation
|
1.245 to 1.272
|
-
|
-
|
|
Carbol fuchsin topical solution
|
Pharmaceutical preparation
|
0.990 to 1.050
|
-
|
-
|
|
Chlorhexidine gluconate solution
|
Pharmaceutical preparation
|
1.06 to 1.07
|
-
|
-
|
|
Compound benzoin tincture
|
Pharmaceutical preparation
|
0.870 to 0.885
|
-
|
-
|
|
Glutaral concentrate
|
Pharmaceutical preparation
|
1.126 to 1.135 at 20 °C
|
-
|
-
|
|
Iron sucrose injection
|
Pharmaceutical preparation
|
1.135 to 1.165 at 20 °C
|
-
|
-
|
|
Mibolerone oral solution
|
Pharmaceutical preparation
|
1.030 to 1.045
|
-
|
-
|
|
Nitromersol topical solution
|
Pharmaceutical preparation
|
1.005 to 1.010
|
-
|
-
|
|
Padimate O
|
Pharmaceutical preparation
|
0.990 to 1.000
|
1.5390 to 1.5430
|
-
|
|
Rubbing alcohol
|
Pharmaceutical preparation
|
0.8691 to 0.8771 at 15.56 °C
|
-
|
-
|
|
Sodium phosphates oral solution
|
Pharmaceutical preparation
|
1.333 to 1.366
|
-
|
-
|
|
Sodium phosphates rectal solution
|
Pharmaceutical preparation
|
1.112 to 1.136
|
-
|
-
|
|
Witch hazel
|
Pharmaceutical preparation
|
0.979 to 0.983
|
-
|
-
|
|
Zinc sulfate oral solution
|
Pharmaceutical preparation
|
1.18 to 1.24
|
-
|
-
|
|
Alcohol
|
Solvent
|
0.812 to 0.816 at 15.56 °C
|
-
|
-
|
|
Dehydrated alcohol
|
Solvent
|
*NMT 0.7962 at 15.56 °C
|
-
|
-
|
|
Dehydrated alcohol injection
|
Solvent
|
*NMT 0.8035 at 15.56 °C
|
-
|
-
|
|
Diluted alcohol
|
Solvent
|
0.935 to 0.937 at 15.56 °C (41.0 % to 42.0 % by weight)
|
-
|
-
|
|
Azeotropic isopropyl alcohol
|
Solvent
|
0.815 to 0.810
|
1.376 to 1.378 at 20 °C
|
-
|
|
Acetone
|
Solvent
|
*NMT 0.789
|
-
|
-
|
|
Isopropyl alcohol
|
Solvent
|
0.783 to 0.787
|
1.376 to 1.378 at 20 °C
|
-
|
|
Isopropyl rubbing alcohol
|
Solvent
|
0.872 to 0.883 at 20 °C
|
-
|
-
|
|
Ether
|
Solvent
|
0.713 to 0.716, indicating 96.0 % to 98.0 % of C4H10O
|
-
|
-
|
|
Ethyl acetate
|
Solvent
|
0.894 to 0.898
|
-
|
-
|
|
Ethylene glycol
|
Solvent
|
about 1.11
|
-
|
-
|
|
Isobutyl acetate
|
Solvent
|
0.863 to 0.868
|
1.3900 to 1.3920 at 20 °C
|
-
|
|
Methylene chloride
|
Solvent
|
1.318 to 1.322
|
-
|
-
|
|
Dimethyl sulfoxide
|
Solvent
|
1.095 to 1.101
|
1.4755 to 1.4775
|
-
|
|
Acetophenone
|
Solvent
|
about 1.03
|
about 1.534 at 20 °C
|
-
|
|
Propylene glycol
|
Solvent
|
1.035 to 1.037
|
-
|
-
|
|
2-Ethoxyethanol
|
Solvent
|
about 0.93
|
-
|
-
|
|
Methyl acetate
|
Solvent
|
about 0.933
|
1.3615 to 1.3625 at 20 °C
|
-
|
|
Methyl isobutyl ketone
|
Solvent
|
*NMT 0.799
|
-
|
-
|
|
Ethyl butyrate
|
Solvent
|
0.870 to 0.877 at 25 °C
|
-
|
-
|
|
Propylene glycol diacetate
|
Solvent
|
1.040 to 1.060
|
1.4130 to 1.4150 at 20 °C
|
-
|
|
Propylene carbonate
|
Solvent
|
1.203 to 1.210 at 20 °C
|
-
|
-
|
|
tert-Amyl alcohol
|
Solvent
|
about 0.81
|
-
|
-
|
|
Acetyl chloride
|
Reagent
|
about 1.1
|
-
|
-
|
|
Benzaldehyde
|
Reagent
|
1.041 to 1.046
|
1.5440 to 1.5465 at 20 °C
|
-
|
|
Formic acid
|
Reagent
|
1.217 to 1.223 at 20 °C
|
-
|
-
|
|
Cresol
|
Reagent
|
1.030 to 1.038
|
-
|
-
|
|
Butyrolactone
|
Reagent
|
1.128 to 1.135
|
about 1.435 at 20 °C
|
-
|
|
Dibutyl phthalate
|
Reagent
|
1.043 to 1.048 at 20 °C
|
1.490 to 1.495 at 20 °C
|
-
|
|
Ethyl cyanoacetate
|
Reagent
|
1.057 to 1.062
|
-
|
-
|
|
Monothioglycerol
|
Reagent
|
1.241 to 1.250
|
1.521 to 1.526
|
-
|
|
o-Toluidine
|
Reagent
|
-
|
1.008 at 20 °C
|
200 ° to 202 °
|
|
Monoethanolamine
|
Reagent
|
1.013 to 1.016
|
-
|
-
|
|
Glycerin
|
Additive
|
**NLT 1.249
|
-
|
-
|
|
Phenoxyethanol
|
Additive
|
1.105 to 1.110 at 20 °C
|
1.391 to 1.394 at 20 °C
|
-
|
|
Phenylethyl alcohol
|
Additive
|
1.017 to 1.020
|
1.531 to 1.534 at 20 °C
|
-
|
|
Polydimethylsiloxane, viscosity 0.65 centistokes
|
Additive
|
about 0.760
|
about 1.3770
|
-
|
|
Propionic acid
|
Additive
|
0.988 to 0.993
|
-
|
-
|
|
Purified honey
|
Additive
|
1.400 to 1.435 at 20 °C
|
1.4900 to 1.4992 at 20 °C
|
-
|
|
Hexylene glycol
|
Additive
|
0.917 to 0.923
|
1.424 to 1.430
|
-
|
|
Alkyl (C12-15) benzoate
|
Emollient
|
0.915 to 0.935
|
1.483 to 1.487 at 20 °C
|
-
|
|
Almond oil
|
Emollient
|
0.910 to 0.915
|
-
|
-
|
|
Canola oil
|
Emollient
|
0.906 to 0.920
|
1.465 to 1.467 at 40 °C
|
-
|
|
Castor oil
|
Emollient
|
0.957 to 0.961
|
-
|
-
|
|
Diethyl sebacate
|
Emollient
|
0.958 to 0.968 at 20 °C
|
1.435 to 1.437 at 20 °C
|
-
|
|
Hydrogenated polydecene
|
Emollient
|
Type I 0.814-0.819; Type II 0.823-0.827; Type III 0.828-0.832
|
-
|
-
|
|
Isopropyl myristate
|
Emollient
|
0.846 to 0.854
|
1.432 to 1.436 at 20 °C
|
-
|
|
Isopropyl palmitate
|
Emollient
|
0.850 to 0.855
|
1.435 to 1.438
|
-
|
|
Light mineral oil
|
Emollient
|
0.93 to 0.96 at 20 °C
|
-
|
-
|
|
Medium-chain triglycerides
|
Emollient
|
0.93 to 0.96 at 20 °C
|
1.440 to 1.452 at 20 °C
|
-
|
|
Mineral oil
|
Emollient
|
0.845 to 0.905
|
-
|
-
|
|
Oleyl oleate
|
Emollient
|
0.860 to 0.884 at 20 °C
|
1.464 to 1.468 at 20 °C
|
-
|
|
Petrolatum
|
Emollient
|
0.815 to 0.880 at 60 °C
|
-
|
-
|
|
Sesame oil
|
Emollient
|
0.912 to 0.921
|
-
|
-
|
|
Squalane
|
Emollient
|
0.807 to 0.810 at 20 °C
|
1.4510 to 1.4525 at 20 °C
|
-
|
|
Topical light mineral oil
|
Emollient
|
0.818 to 0.880
|
-
|
-
|
|
White petrolatum
|
Emollient
|
0.815 to 0.880 at 60 °C
|
-
|
-
|
|
Polyoxyl 35 castor oil
|
Emulsifier
|
1.05 to 1.06
|
-
|
-
|
|
Polysorbate 80
|
Emulsifier
|
1.06 to 1.09
|
-
|
-
|
|
Tributhyl citrate
|
Plasticizer
|
1.037 to 1.045
|
1.443 to 1.445
|
-
|
|
Anethole
|
Natural product extract/preparation
|
0.983 to 0.988
|
1.557 to 1.561
|
-0.15 ° to +0.15 °
|
|
Caraway oil
|
Natural product extract/preparation
|
0.900 to 0.910
|
1.484 to 1.488 at 20 °C
|
+70 ° to +80 °
|
|
Cardamom oil
|
Natural product extract/preparation
|
0.917 to 0.947
|
1.463 to 1.466 at 20 °C
|
+22 ° to +44 °
|
|
Cherry juice
|
Natural product extract/preparation
|
1.045 to 1.075
|
**NLT 1.350
|
-
|
|
Clove oil
|
Natural product extract/preparation
|
1.038 to 1.060
|
1.527 to 1.535 at 20 °C
|
*NMT -1.5 °
|
|
Coriander oil
|
Natural product extract/preparation
|
0.863 to 0.875
|
1.462 to 1.472 at 20 °C
|
+8 ° to +15 °
|
|
Eucalyptol
|
Natural product extract/preparation
|
0.921 to 0.924
|
1.455 to 1.460 at 20 °C
|
-0.5 ° to +0.5 °
|
|
Eucalyptus oil
|
Natural product extract/preparation
|
0.906 to 0.927 at 20 °C
|
1.450 to 1.470 at 20 °C
|
0 ° to 10 ° at 20 °
|
|
Eugenol
|
Natural product extract/preparation
|
1.064 to 1.070
|
1.540 to 1.542 at 20 °C
|
-
|
|
Fennel oil
|
Natural product extract/preparation
|
0.953 to 0.973
|
1.528 to 1.538 at 20 °C
|
+12 ° to +24 °
|
|
Ginger tincture
|
Natural product extract/preparation
|
0.90 to 0.95
|
-
|
-
|
|
Lemon oil
|
Natural product extract/preparation
|
0.849 to 0.855
|
1.473 to 1.476 at 20
|
+57 ° to +65.6 °
|
|
Orange oil
|
Natural product extract/preparation
|
0.842 to 0.846
|
1.472 to 1.474 at 20 °C
|
+94 ° to +99 °
|
|
Peppermint oil
|
Natural product extract/preparation
|
0.896 to 0.908
|
1.459 to 1.465 at 20 °C
|
-18 ° to -32 °
|
|
Rose oil
|
Natural product extract/preparation
|
SG30/15: 0.848 to 0.863
|
1.457 to 1.463 at 30 °C
|
-1 ° to -4 °
|
|
Caramel
|
Flavoring agent
|
**NLT 1.30
|
-
|
-
|
|
2,3-Butanedione
|
Flavoring agent
|
about 0.98
|
1.3935 to 1.3965 at 20 °C
|
-
|
|
Allyl isothiocyanate
|
Flavoring agent
|
1.013 to 1.020
|
1.527 to 1.531 at 20 °C
|
-
|
|
Syrup
|
Flavoring agent
|
**NLT 1.30
|
-
|
-
|
|
Cod liver oil
|
Nutritional supplement
|
0.918 to 0.927
|
-
|
-
|
|
Crypthecodinium cohnii oil
|
Nutritional supplement
|
0.91 to 0.93
|
-
|
-
|
|
Crypthecodinium cohnii oil capsules
|
Nutritional supplement
|
0.91 to 0.93
|
-
|
-
|