For engine and gear oils ccording to the SAE standards J 300 and J 306
The viscosity grade of a lube oil is determined by the Society of Automotive Engineers (SAE). Oils can be separated into multigrade oils and monograde oils. Multigrade oils must fulfill two viscosity specifications, their viscosity grade consists of two numbers, e.g. 10W-40: 10W refers to the low-temperature viscosity ("Winter"), 40 refers to the high-temperature viscosity ("Summer"). Currently, most automotive engine oils are multigrade oils, while oils for restricted usage, e.g. for seasonally used engines like lawn mowers, are often monograde oils. While the two numbers specify the SAE viscosity grade, the viscosity index shows the temperature related change of viscosity.
This page gives an overview of the oil specifications, see also the measurement data of engine oils and gear oils over a wide temperature range.
High-Temperature Viscosities
| SAE Viscosity Grade[°C] | Min. Viscosity [mm²/s] at 100 °C | Max. Viscosity [mm²/s] at 100 °C | High Shear Rate Viscosity [mPa.s] at 150 °C |
|---|---|---|---|
| 0W | 3.8 | -- | -- |
| 5W | 3.8 | -- | -- |
| 10W | 4.1 | -- | -- |
| 15W | 5.6 | -- | -- |
| 20W | 5.6 | -- | -- |
| 25W | 9.3 | -- | -- |
| 20 | 5.6 | <9.3 | 2.6 |
| 30 | 9.3 | <12.5 | 2.9 |
| 40 | 12.5 | <16.3 | 2.9 * |
| 40 | 12.5 | <16.3 | 3.7 ** |
| 50 | 16.3 | <21.9 | 3.7 |
| 60 | 21.9 | <26.1 | 3.7 |
* 0W-40, 5W-40 & 10W-40 grades
** 15W-40, 20W-40, 25W-40 & 40 grades
| SAE Viscosity Grade[°C] | Cranking Viscosity [mPa.s] max. at Temp. [°C] | Pumping Viscosity [mPa.s] max. at Temp. [°C] |
|---|---|---|
| 0W | 6200 at -35 | 60 000 at -40 |
| 5W | 6600 at -30 | 60 000 at -35 |
| 10W | 7000 at -25 | 60 000 at -30 |
| 15W | 7000 at -20 | 60 000 at -25 |
| 20W | 9500 at -15 | 60 000 at -20 |
| 25W | 13 000 at -10 | 60 000 at -15 |
| 20 | -- | -- |
| 30 | -- | -- |
| 40 | -- | -- |
| 40 | -- | -- |
| 50 | -- | -- |
| 60 | -- | -- |
| SAE Viscosity Grade | Max. Temperature for 150 000 cP [°C] (ASTM D 2983) | Min. Viscosity [mm²/s] at 100 °C (ASTM D445) | Max. Viscosity [mm²/s] at 100 °C (ASTM D445) |
|---|---|---|---|
| 70W | -55 | 3.72 | -- |
| 75W | -40 | 4.4 | -- |
| 80W | -26 | 5.29 | -- |
| 85W | -12 | 6.46 | -- |
| 80 | -- | 8.02 | <11.0 |
| 85 | -- | 10.15 | <13.5 |
| 90 | -- | 13.13 | <18.5 |
| 110 | -- | 17.4 | <24.0 |
| 140 | -- | 23.74 | <32.5 |
| 190 | -- | 33.33 | <41.0 |
| 250 | -- | 48.49 | -- |
SAE J 300, SAE J 306
| Reference | SAE J 300, SAE J 306 |
|---|---|
| Kin. vis. | yes |
| Dyn. vis. | no |
| Density | no |
| Multiple temperatures | no |
| Related | kinematic viscosity, viscosity, engine oil, gear oil, lubricant, lube oil, SAE J 300, SAE J 306, viscosity grade |