1 Rates

X-ray Analysis: An Introduction to Techniques for Material Characterization

What is X-ray Analysis?

X-ray analysis refers to a group of analytical techniques that utilize X-rays to investigate the structure, composition, and properties of materials. The associated methods are widely used across scientific research, industrial quality control, and material characterization and distinguishable from each other based on the interactions between the X-rays and the material. 

By measuring the interactions—whether X-rays are absorbed, scattered, or emitted—these techniques provide valuable information about the atomic and molecular structure of materials.

How Does X-ray Analysis Work?

X-ray analysis techniques are based on the interaction between X-ray photons and the atoms in a material. When X-rays hit a material, they can be scattered, absorbed, or cause the emission of secondary radiation. 

These interactions produce distinct patterns or signals that can be analyzed to gain insights into the material’s composition, crystalline structure, or elemental distribution.

There are two primary types of X-ray interactions utilized in material characterization:

  • X-ray diffraction (XRD): Focuses on how X-rays are diffracted by the internal atomic arrangement of the crystal lattice.
  • X-ray fluorescence (XRF): Analyzes the secondary X-rays emitted from a material when it is excited by a primary X-ray source to determine the chemical composition of the material.

Common X-ray Analysis Techniques

Here are three of the most widely used X-ray analysis methods for qualitative and quantitative material characterization:

X-ray diffraction (XRD)

X-ray diffraction (XRD) is one of the most commonly used techniques for determining the crystal structure of materials. When X-rays interact with the periodically arranged atoms in a crystal, they are diffracted to specific angles. These diffraction patterns provide information about the atomic arrangement within the material.

Key information obtained with XRD

  • Phase identification: XRD is used to identify the crystal phases present in a material by either comparing diffraction patterns with known standards or through matching the diffraction data (peak positions and intensities) to a structural database.
  • Crystallinity: It is possible to determine the degree of crystallinity in a sample, essential in materials like polymers, ceramics, and metals.
  • Stress and strain analysis: XRD can detect changes in lattice spacing, revealing internal stresses or strains in materials.
  • Quantitative phase analysis: XRD allows the quantification of phase fractions.

Industries

XRD is extensively used in industries such as pharmaceuticals, ceramics, metals, and electronics for quality control and R&D.

X-ray fluorescence (XRF)

X-ray fluorescence (XRF) is a powerful technique used for elemental analysis. When a material is bombarded with high-energy X-rays, electrons can be expelled from its atoms, leaving a vacant electron orbital behind. By refilling the vacant orbital with an outer-shell electron, secondary X-rays characteristic of the elements present are released. By measuring the energy and intensity of these emitted X-rays, the elemental composition of a sample can be determined.

Key applications of XRF

  • Elemental composition analysis: XRF uses matrix-specific calibrations to quantify the elemental composition of a material.
  • Geological and environmental studies: XRF is frequently used in mining, soil analysis, and environmental monitoring to detect trace elements.
  • Industrial quality control: XRF is used for rapid, non-destructive testing of materials in industries such as metal, cement, and glass production.

Industries

XRF is widely used in environmental science, metallurgy, archaeology, and materials science.

Small-angle X-ray scattering (SAXS)

Small-angle X-ray scattering (SAXS) is a technique that examines how X-rays are scattered at small angles by the material’s nanostructure. SAXS is particularly useful for studying materials with features in the nanometer to micrometer range.

Key applications of SAXS

  • Nanomaterial characterization: SAXS is used to analyze the size, shape, and distribution of nanoparticles, polymers, and proteins.
  • Structure of soft matter: It provides insights into the structure of soft materials like gels, colloids, and biological samples.
  • Porosity and surface area analysis: SAXS helps in determining the porosity and surface area in materials like catalysts and porous solids.

Industries

SAXS finds applications in materials science, pharmaceuticals, and nanotechnology.

Qualitative vs. Quantitative Analysis in X-ray Methods

X-ray analysis methods can be divided into two primary categories:

Qualitative analysis

Qualitative analysis provides information about the types of elements or phases present in a material. For example, XRF identifies which elements are present based on the characteristic X-rays emitted, and XRD identifies crystalline phases by matching diffraction patterns with known patterns coming from databases.

Quantitative analysis

Quantitative analysis determines the amount or concentration of elements or phases. In XRF, this is done by measuring the intensity of the emitted X-rays, which is proportional to the concentration of the elements. In XRD, the relative intensities of diffraction peaks can be used to quantify phase fractions in a material.

Advantages of X-ray Analysis

  • Non-destructive: X-ray analysis does not alter the sample, making it ideal for testing valuable or delicate materials.
  • Versatile: X-ray techniques can be applied to a wide range of materials, including metals, ceramics, polymers, and biological samples.
  • Multi-scale analysis: Techniques like SAXS and Powder XRD provide insights from the atomic to the nanoscale, allowing comprehensive material characterization for a large number of crystallites.
  • Fast and efficient: Many X-ray methods allow for rapid data collection, making them suitable for both research and industrial quality control.

Conclusion

X-ray analysis offers a diverse range of techniques for both qualitative and quantitative material characterization. Whether determining the crystal structure through XRD or identifying elemental composition with XRF, these methods provide crucial insights across industries. From research labs to industrial production lines, X-ray analysis is indispensable for understanding and improving material properties.