Jet fuels and aviation gasolines used in civil and military aircrafts.
Description
Aviation fuels in general are fuels suitable for use in aircrafts powered by turbojet, turboprop or piston engines. They consist mainly of hydrocarbons (paraffins, cycloparaffins, naphthenes, aromatics and olefins, whereby paraffins and cycloparaffins are the main components. Depending on their specific use they additionally contain additives.
The following aviation fuel types are available:
Kerosene - Jet A-1 is the most common type in civil aviation, JP-8 is the military equivalent, TS-1 has improved low-temperature properties. It must fulfill viscosity specifications.
Wide-cut fuels: These are a mixture of kerosene and gasoline and can be used in an extended temperature range. Wide-cut fuels must fulfill a density specification, but not all of them must fulfill viscosity specifications.
High flash point kerosene: Provides more fire security because of a min. flash point of 60 °C. Must fulfill viscosity specifications.
Low volatility kerosene: Gives good thermal stability and contains only a low amount of highly volatile components like toluene or benzene. Must fulfill viscosity specifications.
Aviation gasoline: Also known as AVGAS, only for use with piston or Wankel engines. No viscosity specifications.
Low Temperature Scans on Jet Fuels
In order for jet fuel to endure long cold soak periods at temperatures believed to be -40°C or lower, knowing the viscosity of jet fuel at such low temperatures becomes increasingly important. This is especially relevant for so-called Auxiliary Power Units (APUs), which are small gas turbines that need to start up on command. These APUs can be inactive for long periods (15 hours or more) at flying height. During these periods, the fuel's temperature drops down to ambient temperature. The APUs' ability to start depends on the viscosity of the jet fuel at such low temperatures. Too high viscosity prevents fine enough atomization of the jet fuel - consequently, droplet evaporation is not possible.
Data are available for two different jet fuels and a jet fuel reference standard. While fuel JF1107 is type Jet A, fuel JF1411 is type Jet A1. The fuels differ in their freeze point specifications (-40 °C for JET A and -47 °C for Jet A1). Therefore typically viscosity of JET A is higher and JET A also shows a steeper increase of viscosity with decreasing temperatures.
Jet A JF1107 was tested as a range scan from -20°C to -55°C with 1°C steps. Test duration: 2h 15 min.
Jet A1 JF1411 and reference standard Jet N2B were tested as tables scan with variable steps from -20°C to -56°C. Test duration: 1h 40 min.
All samples were filled at +20°C. With filling, cleaning and drying at -20°C, which requires a supply of dry air, approximately 15 minutes can be saved.
En nuestro sitio web utilizamos cookies. Algunas de ellas son necesarias (por ejemplo, para el carrito), otras nos ayudan a hacer que nuestro contenido en línea sea mejor y más fácil para usted, a largo plazo a través de análisis, medios externos y servicios de marketing. Con su consentimiento (Art. 49(1)(a) GDPR) podemos utilizar cookies de terceros de proveedores de Estados Unidos como Google o Facebook. Sus datos pueden ser transferidos a Estados Unidos, que no tiene un nivel de protección de datos comparable al del GDPR. En este caso, las autoridades estadounidenses podrían acceder a sus datos con fines de vigilancia y es posible que usted no pueda ejercer recursos legales efectivos. Puede aceptar todas las cookies haciendo clic en el botón, o definir su configuración de cookies utilizando el enlace "Customize your cookie settings" (personalizar su configuración de cookies).
Si rechaza todas las cookies, sólo se utilizarán las cookies técnicamente necesarias. También puede retirar su consentimiento en un momento posterior accediendo a la configuración de las cookies.
Las cookies de marketing son utilizadas por terceros o editores para mostrarle publicidad personalizada. Lo hacen rastreando a qué sitios web se dirigen los visitantes.
Recopilamos y combinamos datos sobre nuestros visitantes y sobre su comportamiento en nuestro sitio web. Esta información se utiliza para mejorar el sitio web.
El contenido de las redes sociales y las plataformas de video está bloqueado de manera predeterminada. Si acepta cookies de medios externos, acceder a esos contenidos ya no requiere el consentimiento manual.
Después de haber sido informado sobre los riesgos potenciales para mis datos (que incluyen la transferencia de datos a los EE.UU. y el posible acceso por parte de las autoridades estadounidenses) en el Banner de Cookies y la Política de Privacidad, acepto las cookies de los proveedores estadounidenses.