Ethanol (C2H5OH)
Percentage by weight according to W. Kaempf, based on true density at 20 °C
Ethanol, also called ethyl alcohol, is a volatile, flammable, colorless liquid with the structural formula CH3CH2OH (often abbreviated as C2H5OH or C2H6O).
Ethanol is a psychoactive drug and one of the oldest recreational drugs still used by humans. Ethanol can cause alcohol intoxication when consumed.
Best known as the type of alcohol found in alcoholic beverages, it is also used in thermometers, as solvent, and as a fuel.
| g/cm3 | % w/w |
|---|---|
| 0.998190 | 0.00 |
| 0.998170 | 0.01 |
| 0.998151 | 0.02 |
| 0.998131 | 0.03 |
| 0.998111 | 0.04 |
| 0.998091 | 0.05 |
| 0.998071 | 0.06 |
| 0.998051 | 0.07 |
| 0.998041 | 0.08 |
| 0.998021 | 0.09 |
| 0.998001 | 0.10 |
| 0.997981 | 0.11 |
| 0.997961 | 0.12 |
| 0.997941 | 0.13 |
| 0.997921 | 0.14 |
| 0.997901 | 0.15 |
| 0.997881 | 0.16 |
| 0.997861 | 0.17 |
| 0.997841 | 0.18 |
| 0.997822 | 0.19 |
| 0.997802 | 0.20 |
| 0.997792 | 0.21 |
| 0.997772 | 0.22 |
| 0.997752 | 0.23 |
| 0.997732 | 0.24 |
| 0.997712 | 0.25 |
| 0.997692 | 0.26 |
| 0.997672 | 0.27 |
| 0.997652 | 0.28 |
| 0.997632 | 0.29 |
| 0.997612 | 0.30 |
| 0.997592 | 0.31 |
| 0.997572 | 0.32 |
| 0.997562 | 0.33 |
| 0.997542 | 0.34 |
| 0.997522 | 0.35 |
| 0.997503 | 0.36 |
| 0.997483 | 0.37 |
| 0.997463 | 0.38 |
| 0.997443 | 0.39 |
| 0.997423 | 0.40 |
| 0.997403 | 0.41 |
| 0.997383 | 0.42 |
| 0.997363 | 0.43 |
| 0.997353 | 0.44 |
| 0.997333 | 0.45 |
| 0.997313 | 0.46 |
| 0.997293 | 0.47 |
| 0.997273 | 0.48 |
| 0.997253 | 0.49 |
| 0.997233 | 0.50 |
| 0.997213 | 0.51 |
| 0.997193 | 0.52 |
| 0.997173 | 0.53 |
| 0.997164 | 0.54 |
| 0.997144 | 0.55 |
| 0.997124 | 0.56 |
| 0.997104 | 0.57 |
| 0.997084 | 0.58 |
| 0.997064 | 0.59 |
| 0.997044 | 0.60 |
| 0.997024 | 0.61 |
| 0.997004 | 0.62 |
| 0.996994 | 0.63 |
| 0.996974 | 0.64 |
| 0.996954 | 0.65 |
| 0.996934 | 0.66 |
| 0.996914 | 0.67 |
| 0.996894 | 0.68 |
| 0.996874 | 0.69 |
| 0.996854 | 0.70 |
| 0.996835 | 0.71 |
| 0.996825 | 0.72 |
| 0.996805 | 0.73 |
| 0.996785 | 0.74 |
| 0.996765 | 0.75 |
| 0.996745 | 0.76 |
| 0.996725 | 0.77 |
| 0.996705 | 0.78 |
| 0.996685 | 0.79 |
| 0.996675 | 0.80 |
| 0.996655 | 0.81 |
| 0.996635 | 0.82 |
| 0.996615 | 0.83 |
| 0.996595 | 0.84 |
| 0.996575 | 0.85 |
| 0.996555 | 0.86 |
| 0.996535 | 0.87 |
| 0.996525 | 0.88 |
| 0.996506 | 0.89 |
| 0.996486 | 0.90 |
| 0.996466 | 0.91 |
| 0.996446 | 0.92 |
| 0.996426 | 0.93 |
| 0.996406 | 0.94 |
| 0.996396 | 0.95 |
| 0.996376 | 0.96 |
| 0.996356 | 0.97 |
| 0.996336 | 0.98 |
| 0.996316 | 0.99 |
| 0.996296 | 1.00 |
| 0.996276 | 1.01 |
| 0.996256 | 1.02 |
| 0.996246 | 1.03 |
| 0.996226 | 1.04 |
| 0.996206 | 1.05 |
| 0.996186 | 1.06 |
| 0.996167 | 1.07 |
| 0.996147 | 1.08 |
| 0.996127 | 1.09 |
| 0.996117 | 1.10 |
| 0.996097 | 1.11 |
| 0.996077 | 1.12 |
| 0.996057 | 1.13 |
| 0.996037 | 1.14 |
| 0.996017 | 1.15 |
| 0.995997 | 1.16 |
| 0.995987 | 1.17 |
| 0.995967 | 1.18 |
| 0.995947 | 1.19 |
| 0.995927 | 1.20 |
| 0.995907 | 1.21 |
| 0.995887 | 1.22 |
| 0.995877 | 1.23 |
| 0.995857 | 1.24 |
| 0.995838 | 1.25 |
| 0.995818 | 1.26 |
| 0.995798 | 1.27 |
| 0.995778 | 1.28 |
| 0.995758 | 1.29 |
| 0.995748 | 1.30 |
| 0.995728 | 1.31 |
| 0.995708 | 1.32 |
| 0.995688 | 1.33 |
| 0.995668 | 1.34 |
| 0.995648 | 1.35 |
| 0.995638 | 1.36 |
| 0.995618 | 1.37 |
| 0.995598 | 1.38 |
| 0.995578 | 1.39 |
| 0.995558 | 1.40 |
| 0.995538 | 1.41 |
| 0.995528 | 1.42 |
| 0.995509 | 1.43 |
| 0.995489 | 1.44 |
| 0.995469 | 1.45 |
| 0.995449 | 1.46 |
| 0.995429 | 1.47 |
| 0.995419 | 1.48 |
| 0.995399 | 1.49 |
| 0.995379 | 1.50 |
| 0.995359 | 1.51 |
| 0.995339 | 1.52 |
| 0.995319 | 1.53 |
| 0.995309 | 1.54 |
| 0.995289 | 1.55 |
| 0.995269 | 1.56 |
| 0.995249 | 1.57 |
| 0.995229 | 1.58 |
| 0.995219 | 1.59 |
| 0.995199 | 1.60 |
| 0.995180 | 1.61 |
| 0.995160 | 1.62 |
| 0.995140 | 1.63 |
| 0.995120 | 1.64 |
| 0.995110 | 1.65 |
| 0.995090 | 1.66 |
| 0.995070 | 1.67 |
| 0.995050 | 1.68 |
| 0.995030 | 1.69 |
| 0.995020 | 1.70 |
| 0.995000 | 1.71 |
| 0.994980 | 1.72 |
| 0.994960 | 1.73 |
| 0.994940 | 1.74 |
| 0.994920 | 1.75 |
| 0.994910 | 1.76 |
| 0.994890 | 1.77 |
| 0.994870 | 1.78 |
| 0.994851 | 1.79 |
| 0.994831 | 1.80 |
| 0.994821 | 1.81 |
| 0.994801 | 1.82 |
| 0.994781 | 1.83 |
| 0.994761 | 1.84 |
| 0.994741 | 1.85 |
| 0.994731 | 1.86 |
| 0.994711 | 1.87 |
| 0.994691 | 1.88 |
| 0.994671 | 1.89 |
| 0.994651 | 1.90 |
| 0.994641 | 1.91 |
| 0.994621 | 1.92 |
| 0.994601 | 1.93 |
| 0.994581 | 1.94 |
| 0.994561 | 1.95 |
| 0.994551 | 1.96 |
| 0.994531 | 1.97 |
| 0.994512 | 1.98 |
| 0.994492 | 1.99 |
| 0.994472 | 2.00 |
| 0.994462 | 2.01 |
| 0.994442 | 2.02 |
| 0.994422 | 2.03 |
| 0.994402 | 2.04 |
| 0.994382 | 2.05 |
| 0.994372 | 2.06 |
| 0.994352 | 2.07 |
| 0.994332 | 2.08 |
| 0.994312 | 2.09 |
| 0.994292 | 2.10 |
| 0.994282 | 2.11 |
| 0.994262 | 2.12 |
| 0.994242 | 2.13 |
| 0.994222 | 2.14 |
| 0.994202 | 2.15 |
| 0.994192 | 2.16 |
| 0.994173 | 2.17 |
| 0.994153 | 2.18 |
| 0.994133 | 2.19 |
| 0.994123 | 2.20 |
| 0.994103 | 2.21 |
| 0.994083 | 2.22 |
| 0.994063 | 2.23 |
| 0.994043 | 2.24 |
| 0.994033 | 2.25 |
| 0.994013 | 2.26 |
| 0.993993 | 2.27 |
| 0.993973 | 2.28 |
| 0.993963 | 2.29 |
| 0.993943 | 2.30 |
| 0.993923 | 2.31 |
| 0.993903 | 2.32 |
| 0.993883 | 2.33 |
| 0.993873 | 2.34 |
| 0.993854 | 2.35 |
| 0.993834 | 2.36 |
| 0.993814 | 2.37 |
| 0.993804 | 2.38 |
| 0.993784 | 2.39 |
| 0.993764 | 2.40 |
| 0.993744 | 2.41 |
| 0.993724 | 2.42 |
| 0.993714 | 2.43 |
| 0.993694 | 2.44 |
| 0.993674 | 2.45 |
| 0.993654 | 2.46 |
| 0.993644 | 2.47 |
| 0.993624 | 2.48 |
| 0.993604 | 2.49 |
| 0.993584 | 2.50 |
| 0.993574 | 2.51 |
| 0.993554 | 2.52 |
| 0.993534 | 2.53 |
| 0.993515 | 2.54 |
| 0.993505 | 2.55 |
| 0.993485 | 2.56 |
| 0.993465 | 2.57 |
| 0.993445 | 2.58 |
| 0.993425 | 2.59 |
| 0.993415 | 2.60 |
| 0.993395 | 2.61 |
| 0.993375 | 2.62 |
| 0.993355 | 2.63 |
| 0.993345 | 2.64 |
| 0.993325 | 2.65 |
| 0.993305 | 2.66 |
| 0.993285 | 2.67 |
| 0.993275 | 2.68 |
| 0.993255 | 2.69 |
| 0.993235 | 2.70 |
| 0.993215 | 2.71 |
| 0.993205 | 2.72 |
| 0.993186 | 2.73 |
| 0.993166 | 2.74 |
| 0.993146 | 2.75 |
| 0.993136 | 2.76 |
| 0.993116 | 2.77 |
| 0.993096 | 2.78 |
| 0.993076 | 2.79 |
| 0.993066 | 2.80 |
| 0.993046 | 2.81 |
| 0.993026 | 2.82 |
| 0.993006 | 2.83 |
| 0.992996 | 2.84 |
| 0.992976 | 2.85 |
| 0.992956 | 2.86 |
| 0.992936 | 2.87 |
| 0.992926 | 2.88 |
| 0.992906 | 2.89 |
| 0.992886 | 2.90 |
| 0.992867 | 2.91 |
| 0.992857 | 2.92 |
| 0.992837 | 2.93 |
| 0.992817 | 2.94 |
| 0.992807 | 2.95 |
| 0.992787 | 2.96 |
| 0.992767 | 2.97 |
| 0.992747 | 2.98 |
| 0.992737 | 2.99 |
| 0.992717 | 3.00 |
| 0.992697 | 3.01 |
| 0.992677 | 3.02 |
| 0.992667 | 3.03 |
| 0.992647 | 3.04 |
| 0.992627 | 3.05 |
| 0.992607 | 3.06 |
| 0.992597 | 3.07 |
| 0.992577 | 3.08 |
| 0.992557 | 3.09 |
| 0.992547 | 3.10 |
| 0.992528 | 3.11 |
| 0.992508 | 3.12 |
| 0.992488 | 3.13 |
| 0.992478 | 3.14 |
| 0.992458 | 3.15 |
| 0.992438 | 3.16 |
| 0.992418 | 3.17 |
| 0.992408 | 3.18 |
| 0.992388 | 3.19 |
| 0.992368 | 3.20 |
| 0.992358 | 3.21 |
| 0.992338 | 3.22 |
| 0.992318 | 3.23 |
| 0.992298 | 3.24 |
| 0.992288 | 3.25 |
| 0.992268 | 3.26 |
| 0.992248 | 3.27 |
| 0.992228 | 3.28 |
| 0.992218 | 3.29 |
| 0.992199 | 3.30 |
| 0.992179 | 3.31 |
| 0.992169 | 3.32 |
| 0.992149 | 3.33 |
| 0.992129 | 3.34 |
| 0.992109 | 3.35 |
| 0.992099 | 3.36 |
| 0.992079 | 3.37 |
| 0.992059 | 3.38 |
| 0.992049 | 3.39 |
| 0.992029 | 3.40 |
| 0.992009 | 3.41 |
| 0.991989 | 3.42 |
| 0.991979 | 3.43 |
| 0.991959 | 3.44 |
| 0.991939 | 3.45 |
| 0.991929 | 3.46 |
| 0.991909 | 3.47 |
| 0.991889 | 3.48 |
| 0.991879 | 3.49 |
| 0.991860 | 3.50 |
| 0.991840 | 3.51 |
| 0.991820 | 3.52 |
| 0.991810 | 3.53 |
| 0.991790 | 3.54 |
| 0.991770 | 3.55 |
| 0.991760 | 3.56 |
| 0.991740 | 3.57 |
| 0.991720 | 3.58 |
| 0.991700 | 3.59 |
| 0.991690 | 3.60 |
| 0.991670 | 3.61 |
| 0.991650 | 3.62 |
| 0.991640 | 3.63 |
| 0.991620 | 3.64 |
| 0.991600 | 3.65 |
| 0.991590 | 3.66 |
| 0.991570 | 3.67 |
| 0.991550 | 3.68 |
| 0.991531 | 3.69 |
| 0.991521 | 3.70 |
| 0.991501 | 3.71 |
| 0.991481 | 3.72 |
| 0.991471 | 3.73 |
| 0.991451 | 3.74 |
| 0.991431 | 3.75 |
| 0.991421 | 3.76 |
| 0.991401 | 3.77 |
| 0.991381 | 3.78 |
| 0.991371 | 3.79 |
| 0.991351 | 3.80 |
| 0.991331 | 3.81 |
| 0.991311 | 3.82 |
| 0.991301 | 3.83 |
| 0.991281 | 3.84 |
| 0.991261 | 3.85 |
| 0.991251 | 3.86 |
| 0.991231 | 3.87 |
| 0.991211 | 3.88 |
| 0.991202 | 3.89 |
| 0.991182 | 3.90 |
| 0.991162 | 3.91 |
| 0.991152 | 3.92 |
| 0.991132 | 3.93 |
| 0.991112 | 3.94 |
| 0.991102 | 3.95 |
| 0.991082 | 3.96 |
| 0.991062 | 3.97 |
| 0.991052 | 3.98 |
| 0.991032 | 3.99 |
| 0.991012 | 4.00 |
| 0.991002 | 4.01 |
| 0.990982 | 4.02 |
| 0.990962 | 4.03 |
| 0.990942 | 4.04 |
| 0.990932 | 4.05 |
| 0.990912 | 4.06 |
| 0.990892 | 4.07 |
| 0.990882 | 4.08 |
| 0.990863 | 4.09 |
| 0.990843 | 4.10 |
| 0.990833 | 4.11 |
| 0.990813 | 4.12 |
| 0.990793 | 4.13 |
| 0.990783 | 4.14 |
| 0.990763 | 4.15 |
| 0.990743 | 4.16 |
| 0.990733 | 4.17 |
| 0.990713 | 4.18 |
| 0.990693 | 4.19 |
| 0.990683 | 4.20 |
| 0.990663 | 4.21 |
| 0.990643 | 4.22 |
| 0.990633 | 4.23 |
| 0.990613 | 4.24 |
| 0.990593 | 4.25 |
| 0.990583 | 4.26 |
| 0.990563 | 4.27 |
| 0.990544 | 4.28 |
| 0.990534 | 4.29 |
| 0.990514 | 4.30 |
| 0.990494 | 4.31 |
| 0.990484 | 4.32 |
| 0.990464 | 4.33 |
| 0.990444 | 4.34 |
| 0.990434 | 4.35 |
| 0.990414 | 4.36 |
| 0.990394 | 4.37 |
| 0.990384 | 4.38 |
| 0.990364 | 4.39 |
| 0.990344 | 4.40 |
| 0.990334 | 4.41 |
| 0.990314 | 4.42 |
| 0.990304 | 4.43 |
| 0.990284 | 4.44 |
| 0.990264 | 4.45 |
| 0.990254 | 4.46 |
| 0.990234 | 4.47 |
| 0.990215 | 4.48 |
| 0.990205 | 4.49 |
| 0.990185 | 4.50 |
| 0.990165 | 4.51 |
| 0.990155 | 4.52 |
| 0.990135 | 4.53 |
| 0.990115 | 4.54 |
| 0.990105 | 4.55 |
| 0.990085 | 4.56 |
| 0.990065 | 4.57 |
| 0.990055 | 4.58 |
| 0.990035 | 4.59 |
| 0.990015 | 4.60 |
| 0.990005 | 4.61 |
| 0.989985 | 4.62 |
| 0.989975 | 4.63 |
| 0.989955 | 4.64 |
| 0.989935 | 4.65 |
| 0.989925 | 4.66 |
| 0.989905 | 4.67 |
| 0.989885 | 4.68 |
| 0.989866 | 4.69 |
| 0.989856 | 4.70 |
| 0.989836 | 4.71 |
| 0.989826 | 4.72 |
| 0.989806 | 4.73 |
| 0.989786 | 4.74 |
| 0.989776 | 4.75 |
| 0.989756 | 4.76 |
| 0.989746 | 4.77 |
| 0.989726 | 4.78 |
| 0.989706 | 4.79 |
| 0.989696 | 4.80 |
| 0.989676 | 4.81 |
| 0.989656 | 4.82 |
| 0.989646 | 4.83 |
| 0.989626 | 4.84 |
| 0.989606 | 4.85 |
| 0.989596 | 4.86 |
| 0.989576 | 4.87 |
| 0.989566 | 4.88 |
| 0.989547 | 4.89 |
| 0.989527 | 4.90 |
| 0.989517 | 4.91 |
| 0.989497 | 4.92 |
| 0.989477 | 4.93 |
| 0.989467 | 4.94 |
| 0.989447 | 4.95 |
| 0.989437 | 4.96 |
| 0.989417 | 4.97 |
| 0.989397 | 4.98 |
| 0.989387 | 4.99 |
| 0.989367 | 5.00 |
| 0.989347 | 5.01 |
| 0.989337 | 5.02 |
| 0.989317 | 5.03 |
| 0.989307 | 5.04 |
| 0.989287 | 5.05 |
| 0.989267 | 5.06 |
| 0.989257 | 5.07 |
| 0.989237 | 5.08 |
| 0.989218 | 5.09 |
| 0.989208 | 5.10 |
| 0.989188 | 5.11 |
| 0.989178 | 5.12 |
| 0.989158 | 5.13 |
| 0.989138 | 5.14 |
| 0.989128 | 5.15 |
| 0.989108 | 5.16 |
| 0.989088 | 5.17 |
| 0.989078 | 5.18 |
| 0.989058 | 5.19 |
| 0.989048 | 5.20 |
| 0.989028 | 5.21 |
| 0.989008 | 5.22 |
| 0.988998 | 5.23 |
| 0.988978 | 5.24 |
| 0.988968 | 5.25 |
| 0.988948 | 5.26 |
| 0.988928 | 5.27 |
| 0.988918 | 5.28 |
| 0.988898 | 5.29 |
| 0.988879 | 5.30 |
| 0.988869 | 5.31 |
| 0.988849 | 5.32 |
| 0.988839 | 5.33 |
| 0.988819 | 5.34 |
| 0.988799 | 5.35 |
| 0.988789 | 5.36 |
| 0.988769 | 5.37 |
| 0.988759 | 5.38 |
| 0.988739 | 5.39 |
| 0.988719 | 5.40 |
| 0.988709 | 5.41 |
| 0.988689 | 5.42 |
| 0.988679 | 5.43 |
| 0.988659 | 5.44 |
| 0.988639 | 5.45 |
| 0.988629 | 5.46 |
| 0.988609 | 5.47 |
| 0.988599 | 5.48 |
| 0.988579 | 5.49 |
| 0.988560 | 5.50 |
| 0.988550 | 5.51 |
| 0.988530 | 5.52 |
| 0.988520 | 5.53 |
| 0.988500 | 5.54 |
| 0.988480 | 5.55 |
| 0.988470 | 5.56 |
| 0.988450 | 5.57 |
| 0.988440 | 5.58 |
| 0.988420 | 5.59 |
| 0.988400 | 5.60 |
| 0.988390 | 5.61 |
| 0.988370 | 5.62 |
| 0.988360 | 5.63 |
| 0.988340 | 5.64 |
| 0.988320 | 5.65 |
| 0.988310 | 5.66 |
| 0.988290 | 5.67 |
| 0.988280 | 5.68 |
| 0.988260 | 5.69 |
| 0.988240 | 5.70 |
| 0.988230 | 5.71 |
| 0.988211 | 5.72 |
| 0.988201 | 5.73 |
| 0.988181 | 5.74 |
| 0.988171 | 5.75 |
| 0.988151 | 5.76 |
| 0.988131 | 5.77 |
| 0.988121 | 5.78 |
| 0.988101 | 5.79 |
| 0.988091 | 5.80 |
| 0.988071 | 5.81 |
| 0.988051 | 5.82 |
| 0.988041 | 5.83 |
| 0.988021 | 5.84 |
| 0.988011 | 5.85 |
| 0.987991 | 5.86 |
| 0.987981 | 5.87 |
| 0.987961 | 5.88 |
| 0.987941 | 5.89 |
| 0.987931 | 5.90 |
| 0.987911 | 5.91 |
| 0.987901 | 5.92 |
| 0.987882 | 5.93 |
| 0.987862 | 5.94 |
| 0.987852 | 5.95 |
| 0.987832 | 5.96 |
| 0.987822 | 5.97 |
| 0.987802 | 5.98 |
| 0.987792 | 5.99 |
| 0.987772 | 6.00 |
| 0.987752 | 6.01 |
| 0.987742 | 6.02 |
| 0.987722 | 6.03 |
| 0.987712 | 6.04 |
| 0.987692 | 6.05 |
| 0.987682 | 6.06 |
| 0.987662 | 6.07 |
| 0.987642 | 6.08 |
| 0.987632 | 6.09 |
| 0.987612 | 6.10 |
| 0.987602 | 6.11 |
| 0.987582 | 6.12 |
| 0.987572 | 6.13 |
| 0.987553 | 6.14 |
| 0.987533 | 6.15 |
| 0.987523 | 6.16 |
| 0.987503 | 6.17 |
| 0.987493 | 6.18 |
| 0.987473 | 6.19 |
| 0.987463 | 6.20 |
| 0.987443 | 6.21 |
| 0.987423 | 6.22 |
| 0.987413 | 6.23 |
| 0.987393 | 6.24 |
| 0.987383 | 6.25 |
| 0.987363 | 6.26 |
| 0.987353 | 6.27 |
| 0.987333 | 6.28 |
| 0.987313 | 6.29 |
| 0.987303 | 6.30 |
| 0.987283 | 6.31 |
| 0.987273 | 6.32 |
| 0.987253 | 6.33 |
| 0.987243 | 6.34 |
| 0.987224 | 6.35 |
| 0.987214 | 6.36 |
| 0.987194 | 6.37 |
| 0.987174 | 6.38 |
| 0.987164 | 6.39 |
| 0.987144 | 6.40 |
| 0.987134 | 6.41 |
| 0.987114 | 6.42 |
| 0.987104 | 6.43 |
| 0.987084 | 6.44 |
| 0.987074 | 6.45 |
| 0.987054 | 6.46 |
| 0.987034 | 6.47 |
| 0.987024 | 6.48 |
| 0.987004 | 6.49 |
| 0.986994 | 6.50 |
| 0.986974 | 6.51 |
| 0.986964 | 6.52 |
| 0.986944 | 6.53 |
| 0.986934 | 6.54 |
| 0.986914 | 6.55 |
| 0.986895 | 6.56 |
| 0.986885 | 6.57 |
| 0.986865 | 6.58 |
| 0.986855 | 6.59 |
| 0.986835 | 6.60 |
| 0.986825 | 6.61 |
| 0.986805 | 6.62 |
| 0.986795 | 6.63 |
| 0.986775 | 6.64 |
| 0.986765 | 6.65 |
| 0.986745 | 6.66 |
| 0.986725 | 6.67 |
| 0.986715 | 6.68 |
| 0.986695 | 6.69 |
| 0.986685 | 6.70 |
| 0.986665 | 6.71 |
| 0.986655 | 6.72 |
| 0.986635 | 6.73 |
| 0.986625 | 6.74 |
| 0.986605 | 6.75 |
| 0.986595 | 6.76 |
| 0.986575 | 6.77 |
| 0.986566 | 6.78 |
| 0.986546 | 6.79 |
| 0.986526 | 6.80 |
| 0.986516 | 6.81 |
| 0.986496 | 6.82 |
| 0.986486 | 6.83 |
| 0.986466 | 6.84 |
| 0.986456 | 6.85 |
| 0.986436 | 6.86 |
| 0.986426 | 6.87 |
| 0.986406 | 6.88 |
| 0.986396 | 6.89 |
| 0.986376 | 6.90 |
| 0.986366 | 6.91 |
| 0.986346 | 6.92 |
| 0.986326 | 6.93 |
| 0.986316 | 6.94 |
| 0.986296 | 6.95 |
| 0.986286 | 6.96 |
| 0.986266 | 6.97 |
| 0.986256 | 6.98 |
| 0.986237 | 6.99 |
| 0.986227 | 7.00 |
| 0.986207 | 7.01 |
| 0.986197 | 7.02 |
| 0.986177 | 7.03 |
| 0.986167 | 7.04 |
| 0.986147 | 7.05 |
| 0.986137 | 7.06 |
| 0.986117 | 7.07 |
| 0.986107 | 7.08 |
| 0.986087 | 7.09 |
| 0.986077 | 7.10 |
| 0.986057 | 7.11 |
| 0.986037 | 7.12 |
| 0.986027 | 7.13 |
| 0.986007 | 7.14 |
| 0.985997 | 7.15 |
| 0.985977 | 7.16 |
| 0.985967 | 7.17 |
| 0.985947 | 7.18 |
| 0.985937 | 7.19 |
| 0.985917 | 7.20 |
| 0.985908 | 7.21 |
| 0.985888 | 7.22 |
| 0.985878 | 7.23 |
| 0.985858 | 7.24 |
| 0.985848 | 7.25 |
| 0.985828 | 7.26 |
| 0.985818 | 7.27 |
| 0.985798 | 7.28 |
| 0.985788 | 7.29 |
| 0.985768 | 7.30 |
| 0.985758 | 7.31 |
| 0.985738 | 7.32 |
| 0.985728 | 7.33 |
| 0.985708 | 7.34 |
| 0.985698 | 7.35 |
| 0.985678 | 7.36 |
| 0.985668 | 7.37 |
| 0.985648 | 7.38 |
| 0.985628 | 7.39 |
| 0.985618 | 7.40 |
| 0.985598 | 7.41 |
| 0.985588 | 7.42 |
| 0.985569 | 7.43 |
| 0.985559 | 7.44 |
| 0.985539 | 7.45 |
| 0.985529 | 7.46 |
| 0.985509 | 7.47 |
| 0.985499 | 7.48 |
| 0.985479 | 7.49 |
| 0.985469 | 7.50 |
| 0.985449 | 7.51 |
| 0.985439 | 7.52 |
| 0.985419 | 7.53 |
| 0.985409 | 7.54 |
| 0.985389 | 7.55 |
| 0.985379 | 7.56 |
| 0.985359 | 7.57 |
| 0.985349 | 7.58 |
| 0.985329 | 7.59 |
| 0.985319 | 7.60 |
| 0.985299 | 7.61 |
| 0.985289 | 7.62 |
| 0.985269 | 7.63 |
| 0.985259 | 7.64 |
| 0.985240 | 7.65 |
| 0.985230 | 7.66 |
| 0.985210 | 7.67 |
| 0.985200 | 7.68 |
| 0.985180 | 7.69 |
| 0.985170 | 7.70 |
| 0.985150 | 7.71 |
| 0.985140 | 7.72 |
| 0.985120 | 7.73 |
| 0.985110 | 7.74 |
| 0.985090 | 7.75 |
| 0.985080 | 7.76 |
| 0.985060 | 7.77 |
| 0.985050 | 7.78 |
| 0.985030 | 7.79 |
| 0.985020 | 7.80 |
| 0.985000 | 7.81 |
| 0.984990 | 7.82 |
| 0.984970 | 7.83 |
| 0.984960 | 7.84 |
| 0.984940 | 7.85 |
| 0.984930 | 7.86 |
| 0.984911 | 7.87 |
| 0.984901 | 7.88 |
| 0.984881 | 7.89 |
| 0.984871 | 7.90 |
| 0.984851 | 7.91 |
| 0.984841 | 7.92 |
| 0.984821 | 7.93 |
| 0.984811 | 7.94 |
| 0.984801 | 7.95 |
| 0.984781 | 7.96 |
| 0.984771 | 7.97 |
| 0.984751 | 7.98 |
| 0.984741 | 7.99 |
Ethanol (C2H5OH)
Percentage by weight according to W. Kaempf, based on true density at 20 °C