Viscosity Tables and Viscosity Charts
Find viscosity tables and charts for numerous substances at multiple temperatures.
Substance | Reference | Kin. vis. | Dyn. vis. | Density | Multiple temp. |
---|---|---|---|---|---|
Acetaldehyde | Engineers Edge | no | yes | yes | yes |
Acetic Acid | Kaye & Laby | no | yes | no | yes |
Acetone | Kaye & Laby | no | yes | no | yes |
Acetonitrile | AMVn | no | yes | no | yes |
AGMA Viscosity Classification | AGMA 9005-D94 | yes | no | no | no |
Automatic Transmission Fluid - ATF | SVM™ | yes | yes | yes | yes |
Automotive Antifreeze CT12+ | SVM™ | yes | yes | yes | yes |
Automotive Antifreeze VW G13 | SVM™ | yes | yes | yes | yes |
Automotive Brake Fluids | DOT Specifications, SAE J1703, SAE J1704, J1705, ISO 4925, MIL-PRF-46176, PSA B-712710, SVM™ | yes | no | no | yes |
Aviation Fuels | ASTM D1655, ASTM D7566, GOST 10227-86, MIL-DTL-5624U, MIL-DTL-83133E, MIL-DTL-38219D, GB 6537-2006, Measurement SVM™ | yes | yes | yes | yes |
Benzene | Kaye & Laby, Engineers Edge | no | yes | yes | yes |
Bunker Oil - Marine Fuel Oil | ISO 8217 | yes | no | yes | yes |
Chloroform | Kaye & Laby | yes | yes | no | yes |
Crude Oil | U.S. Energy Information Administration, Genesis Group, USA, Chevron Crude Oil Marketing, Exxon Mobil, AMSA-Australian Maritime Safety Authority | yes | no | yes | yes |
Cyclohexanone | Dynesonline | no | yes | yes | no |
Dichloromethane | Dynesonline | no | yes | yes | no |
Diesel Fuel | EN 590, ASTM D975, DIN EN 14214, ASTM D6751, SVM™ | yes | no | yes | yes |
Dimethyl Sulfoxide | Dynesonline | no | yes | yes | no |
Engine Oil | SVM™ | yes | yes | yes | yes |
Ethanol | Kaye & Laby | no | yes | no | yes |
Flower Honey (Blended) | SVM™ | yes | yes | yes | yes |
Gear Oil | SVM™ | yes | yes | yes | yes |
Heavy Fuel Oil (HFO) - Residual Fuel Oil (RFO) | ASTM D396 | yes | no | yes | yes |
Hexane | Kaye & Laby, Engineers Edge | no | yes | yes | yes |
Hydrofluoric Acid | Lovis 2000 M | no | yes | yes | yes |
Ink | DMA™ 4500 M + Lovis 2000 ME | yes | yes | yes | yes |
ISO Viscosity Classification | ISO 3448 | yes | no | no | no |
Mercury | Rheology Handbook | no | yes | no | no |
Methanol | Kaye & Laby, Engineers Edge, RoyMech and Dynesonline | no | yes | yes | yes |
Nitric Acid | RoyMech | no | yes | no | yes |
Paraffin Wax | SVM™ | yes | yes | yes | yes |
Pentane | Kaye & Laby, Engineers Edge | no | yes | yes | yes |
SAE 0W-30 | SVM™ | yes | yes | yes | yes |
SAE 10W-40 | SVM™ | yes | yes | yes | yes |
SAE 10W-60 | SVM™ | yes | yes | yes | yes |
SAE 15W-40 | SVM™ | yes | yes | yes | yes |
SAE 30 | SVM™ | yes | yes | yes | yes |
SAE 5W-40 | SVM™ | yes | yes | yes | yes |
SAE Viscosity Grades | SAE J 300, SAE J 306 | yes | no | no | no |
Sulfuric Acid | Kaye & Laby, RoyMech | no | yes | no | yes |
Tetrahydrofuran | Dynesonline | no | yes | yes | no |
Toluene | DMA™ 4500 M + Lovis 2000 ME | yes | yes | yes | yes |
Transformer Oils/Process Oils | SVM™ 4001, Abbemat 500 refractometer | yes | no | yes | yes |
Water | IAPWS 2008 | yes | yes | yes | yes |
Whole Blood | Lovis 2000 M | no | yes | no | yes |