Viscosity of Bunker Oil - Marine Fuel Oil
Distillate Fuels, residual Fuels
What is Bunker Oil? - Description and Classification Overview
Bunker oil is generally any type of fuel oil used aboard ships. We can distinguish between two main types: distillate fuels and residual fuels.
Marine fuels are classified using the “Bunker ABC”:
- Bunker A corresponds to the distillate fuel oil No. 2
- Bunker B is a No. 4 or No. 5 fuel oil
- Bunker C corresponds to the residual fuel oil No. 6
No. 6 is the most common oil, that's why "bunker fuel" is often used as a synonym for the No. 6 residual fuel oil which requires heating before the oil can be pumped. No. 5 fuel oil is also called “navy special”. No. 5 or No. 6 also furnace fuel oil (FFO).
In the maritime field another classification is used:
- MGO (Marine Gas Oil): a distillate fuel oil (No. 2, Bunker A)
- MDO (Marine Diesel Oil): a blend of MGO and HFO
- IFO (Intermediate Fuel Oil): a blend of MGO and HFO, with less gasoil than MDO
- MFO (Medium Fuel Oil): a blend of MGO and HFO, with less gasoil than IFO
- HFO (Heavy Fuel Oil): a residual fuel oil (No. 6, Bunker C)
Marine fuels are traditionally classified according to their kinematic viscosity. This is a valid criterion for oil quality as long as the oil is produced by atmospheric distillation only. Today, almost all marine fuels are based on fractions from more advanced refinery processes and the viscosity itself says little about the oil's quality as fuel. Despite this, marine fuels are still quoted on the international bunker markets with their maximum viscosity set by ISO 8217 as marine engines are designed to use different viscosities of fuel. The density is also an important parameter for fuel oils since marine fuels are purified before use to remove water and dirt. Therefore, the oil must have a density which is sufficiently different from water.
Viscosity Tables – Measurement data
Distillate Bunker Oils (ISO 8217)
Distillate Fuel | Kin. Viscosity [mm²/s] at 50°C | Density [g/cm³] at 15°C |
---|---|---|
DMX | 1.4 ... 5.5 | − |
DMA | 1.5 ... 6.0 | < 0.890 |
DMB | < 11 | < 0.900 |
DMC | < 14 | < 0.920 |
Residual Bunker Oils (ISO 8217)
Residual Fuel | Kin. Viscosity [mm²/s] at 50°C | Density [g/cm³] at 15°C |
---|---|---|
RMA 30 | < 30 | < 0.960 |
RMB 30 | < 30 | < 0.975 |
RMD 80 | < 80 | < 0.980 |
RME 180 | < 180 | < 0.991 |
RMF 180 | < 180 | < 0.991 |
RMG 380 | < 380 | < 0.991 |
RMH 380 | < 380 | < 0.991 |
RMK 380 | < 380 | < 1.010 |
RMH 700 | < 700 | < 0.991 |
RMK 700 | < 700 | < 1.010 |
Reference
ISO 8217
Metainformation
Reference | ISO 8217 |
---|---|
Kin. vis. | yes |
Dyn. vis. | no |
Density | yes |
Multiple temperatures | yes |
Related | Bunker oil, marine fuel, bunker C, heavy oil, viscosity, ISO 8217 |